RW65_EX_II Intrinsically Safe Ringbalance Differential Pressure Gauge

ATEX intrinsically safe Ringbalance gauge with local reading and a passive 4-20 mA output.

Part no.RW65_EX_II

  • Supplied and supported by GTi in Thailand
  • Calibration certificate on delivery
  • Selection, installation and commissioning help

Overview

  • Ex-zone, output and limit contact support

Specifications

Intrinsically safe
ATEX approved for gas and dust hazardous areas
Ex-zone suitability
Approved for zones 0, 1, 2, 20, 21 and 22
Local indication
Large 150 x 150 mm analogue dial for on-site reading
4–20 mA output
Passive transmitter output for remote signal transmission
Biogas applications
Suitable for gas accumulator and anaerobic digestion monitoring
Configuration options
Measuring range, scaling, housing and limit sensor options selected to suit the duty
Intrinsically safe Ringbalance gauge
Provides low draft, pressure and differential pressure measurement for hazardous-area applications.
ATEX gas and dust approval
Approved for gas zones 0, 1 and 2, and dust zones 20, 21 and 22 with II 1G and II 1D marking.
Local analogue indication
Large 150 x 150 mm dial supports direct pressure reading at the instrument.
Passive 4–20 mA output
Intrinsically safe transmitter output supports remote pressure monitoring through suitable Ex signal equipment.
Hazardous-area application focus
Suitable for applications such as biogas, anaerobic digestion and gas accumulator pressure monitoring.
Freely selectable range and scaling
Measuring range and scale can be selected to suit the required low-pressure duty.
Optional limit sensing
NAMUR inductive limit contacts can be specified where minimum or maximum switching functionality is required.
Overload protection option
DZ1 or DZ2 overload protection can be considered where excessive differential pressure may occur.
Hazardous-area review
Advice on whether the RW65_EX_II is suitable for the required gas or dust Ex-zone application
Range and scale selection
Support selecting the correct low-pressure measuring range and dial scaling
Limit contact options
Support reviewing NAMUR inductive limit contact requirements where min / max switching is needed
Overload protection
Advice on whether DZ1 or DZ2 overload protection should be considered where pressure spikes or pressure inversion may occur

Not Sure Which Instrument Fits?

Tell us what you need to measure and where. Our engineers match the instrument, supply it with a calibration certificate and help commission it on site.