Skip to main content
Differential Pressure

RW65 Ringbalance Differential Pressure Indicator

Wall-mounted Ringbalance indicator for low draft, pressure, differential pressure and flow in gas and air.

Part no.RW65

  • Supplied and supported by GTi in Thailand
  • Calibration certificate on delivery
  • Selection, installation and commissioning help

Overview

Ranges from 0-40 Pa up to 0-1.8 kPa.

Specifications

Low-pressure indication
Selectable ranges from 0…40 Pa to 0…1.8 kPa
Analogue display
Large 150 x 150 mm scale for clear local reading
Multiple duties
Measures draft, pressure, differential pressure and flow
Contact options
Inductive or mechanical contacts available for switching duties
Industrial housing
IP65 wall-mounted enclosure with hardened front glass
Overload option
DZ overload protection available where pressure spikes may occur
Ringbalance measuring principle
Provides stable local indication for low draft, pressure, differential pressure and flow measurement in gaseous media.
Application-specific range selection
Freely selectable measuring ranges allow the RW65 to be matched to low-pressure duties from 0…40 Pa to 0…1.8 kPa.
No electrical supply required
Mechanical local indication supports pressure reading at the instrument without a dedicated power supply.
Flexible scale configuration
Scale units can be specified in Pa, kPa, daPa, mbar, mmWS, mmCE or in.W.C. to suit site standards.
Optional inductive contacts
NAMUR / ATEX inductive sensors can support minimum, maximum, dual minimum or minimum / maximum switching functions.
Optional mechanical contacts
Mechanical contacts are available for measuring ranges above 200 Pa where simple switching is required.
Industrial wall mounting
IP65 glass-reinforced polycarbonate housing with hardened front glass supports use in demanding plant environments.
Overload protection option
DZ overload protection can be specified where pressure spikes or abnormal overload conditions may exceed standard limits.
Range selection
Support selecting the appropriate measuring range and scale unit for the application
Overload protection
Advice on whether DZ overload protection should be considered where pressure spikes may occur

Not Sure Which Instrument Fits?

Tell us what you need to measure and where. Our engineers match the instrument, supply it with a calibration certificate and help commission it on site.